Solutions · · 6 min read
Mobile data centers are growing by about 18% a year. We explain how the COLDORA Trailer Series adapts easily to this infrastructure and goes into service quickly.
Summary: Mobile and containerized data centers are growing by about 18% a year, driven by the fast capacity demand of AI, 5G and edge computing. This infrastructure goes from order to operation within weeks and needs cooling that can be commissioned just as fast. In this article we look at the rise of mobile data centers and at how COLDORA Trailer Series mobile air conditioners adapt easily to these structures and go into service very quickly.
Why Are Mobile Data Centers on the Rise?
Demand for data center capacity is growing faster than new buildings can be built. AI and analytics clusters call for high-density racks; 5G and edge computing require data to be processed close to users, at thousands of small sites. While a building takes years, containerized and modular data centers are prepared in the factory, brought to site and start operating within weeks.
This demand is reflected in market figures. According to a Mordor Intelligence report published in February 2026, the containerized data center market is expected to grow from USD 20.24 billion in 2026 to USD 46.54 billion in 2031, more than doubling in five years.
Fast-Built Infrastructure Cannot Wait for Cooling
Almost all of the electrical energy supplied to a server turns into heat. A container carrying 100 kW of IT load has to reject roughly 100 kW of heat continuously. When cooling falls short, the temperature inside the racks leaves the safe range within minutes, and servers throttle performance or shut down to protect themselves.
If the container arrives on site within weeks, it makes no sense to wait months for piping and installation work for its cooling. Sites where mobile data centers are set up often have no cooling infrastructure either. Cooling therefore has to be self-contained, ready to connect as soon as it arrives, and able to move with the infrastructure when needed.
COLDORA Trailer Series: Tow It In, Connect It, Run It
The COLDORA Trailer Series consists of 60, 90 and 120 kW monoblock mobile air conditioners mounted on a trailer chassis with a tow bar. Because the entire refrigeration circuit is in a single body, no copper piping is run and no outdoor unit is mounted on site. The unit is towed to site behind a vehicle and is ready for commissioning once the 3-phase (400 V) power connection is made.
Commissioning takes a few simple steps:
- Towing to site: The trailer is brought next to the container with a standard vehicle.
- Positioning: The unit is placed where the air duct can be connected by the shortest route.
- Duct connection: Conditioned air is ducted to the container’s supply opening or to the cold aisle.
- Power connection: The 400 V 3-phase supply is taken from the grid or from the on-site generator.
- Start-up and check: The unit is started, and supply air and rack inlet temperatures are checked.
| Item | Fixed Cooling Installation | COLDORA Trailer Series |
|---|---|---|
| Piping | Installed on site | Not needed (monoblock) |
| Connections needed on site | Piping, power, drainage, controls | Power and air duct |
| Commissioning | Design and installation process | Shortly after arrival on site |
| Relocation | Dismantling and reinstallation | Towed behind a vehicle |
| Adding capacity | Requires a new project | Add a second unit |
| How to obtain | Capital investment | Purchase or rental |
An Easy Fit for Mobile Data Centers
Several design features explain why the Trailer Series adapts so easily to mobile data centers:
- ❄ High static pressure fans: Conditioned air can be carried over long distances through ducts. The unit does not need to sit right next to the container; it can be placed at a convenient spot on site.
- ❄ Stepped capacity: The 60, 90 and 120 kW models make it easy to grow with additional units as the IT load increases in stages.
- ❄ Redundancy (N+1): For critical loads, one extra trailer unit takes over the load when the main cooling fails or is under maintenance.
- ❄ Commissioning and load tests: A new data center is tested with load banks before handover. The heat produced in these tests can be handled by the Trailer Series before the permanent system is ready.
- ❄ Generator compatibility: Because it only needs a 400 V 3-phase supply, it can be included in the data center’s generator plan at sites without grid power.
- ❄ Moves with the infrastructure: When the data center moves to another site, the cooling goes with it, towed behind a vehicle, without being dismantled.
For smaller edge racks, the Monoblock Series (8–14 kW), and for systems that run on chilled water, the Mobile Chiller (20–45 kW, 7/12 °C) offer the same plug-and-play approach.
💡 Pro Tip: When selecting capacity, start from the kW value of your IT load and add UPS losses, lighting and solar gain. Then plan one extra unit (N+1) for critical loads. For a detailed calculation, see our kW–BTU guide.
Portable Cooling for Portable Infrastructure
Mobile data centers let IT infrastructure grow with speed and flexibility. Keeping that flexibility requires cooling that can be set up just as fast and moved just as easily. With a design that is towed to site and put into service quickly with a power connection, and a capacity range of 60–120 kW, the COLDORA Trailer Series meets this need with purchase or rental options. To find the right solution for your project, explore our data center solutions or get in touch with us.